Coupling capacitance is a phenomenon that occurs when two conductors, such as PCB traces and coaxial cables, are placed close to each other. It results in the transfer of electrical energy between the two conductors through the electric field that surrounds them. This can cause a number of problems, such as signal interference, cross-talk, and electromagnetic interference (EMI).

In PCBs, coupling capacitance can occur between adjacent traces on the board. This can cause signal interference and cross-talk, as the electrical energy from one trace can be transferred to another trace, causing unwanted signals to be present on the trace. This can lead to incorrect operation of the circuit or even damage to the components.

In coaxial cables, coupling capacitance can occur between adjacent cables or between a cable and nearby metal objects. This can cause EMI, as the electrical energy from one cable can be transferred to another cable or nearby object, causing unwanted electromagnetic radiation. This can lead to interference with other electronic devices and communication systems.

To address these problems, shielding techniques can be used to reduce coupling capacitance. In PCBs, shielding can be achieved by using a ground plane, which is a layer of metal on the PCB that surrounds the traces and acts as a shield. The ground plane can be connected to the ground of the circuit to reduce the coupling capacitance between adjacent traces.

In coaxial cables, shielding can be achieved by using a braided shield, which is a layer of metal wire that surrounds the inner conductor of the cable. The braided shield can be connected to the ground of the circuit to reduce the coupling capacitance between adjacent cables or between a cable and nearby metal objects.

In both cases, the shielding is based on the principle of electromagnetic shielding, which is the ability of a conductive material to reduce the coupling between two conductors by reducing the electric field that surrounds them. The effectiveness of the shielding is determined by the electrical conductivity of the material used and the distance between the shielded conductors.

The shielding effectiveness can be calculated using the shielding attenuation factor, which is a measure of the reduction in coupling capacitance achieved by the shielding. The shielding attenuation factor is given by:

SAF = 20log10(d1/d2)

Where:

  • SAF = Shielding attenuation factor
  • d1 = Distance between the shielded conductors
  • d2 = Distance between the unshielded conductors

The shielding attenuation factor is expressed in decibels (dB) and the higher the value, the better the shielding effectiveness.

In addition to shielding, other techniques such as using twisted pair cables, which are cables where the two conductors are twisted together, can be used to reduce cross-coupling. This can be achieved by introducing a phase shift between the signals on the two conductors, which makes it difficult for the energy from one conductor to couple with the other.

One of the most widely used solutions for coupling problems is the use of a Faraday cage. A Faraday cage is an enclosure made of a conductive material that surrounds the conductors and blocks the electric fields that cause coupling capacitance. Faraday cages are commonly used in electronic equipment to reduce EMI. The effectiveness of a Faraday cage can be calculated using the shielding attenuation factor, as previously discussed.

Another solution for coupling problems is the use of a twisted pair cable. As mentioned earlier, twisted pair cables are cables where the two conductors are twisted together. This introduces a phase shift between the signals on the two conductors, which makes it difficult for the energy from one conductor to couple with the other. The amount of twisting can be adjusted to optimize the amount of phase shift and reduce coupling.

The use of twisted pair cables is based on the principle of differential signaling. This is a method of transmitting data where the two conductors in the twisted pair cable are used to transmit two complementary signals. The receiver then compares the two signals and only the difference between them is used to recover the data. This method is highly effective in reducing the effects of coupling capacitance and EMI.

Another solution for coupling problems is the use of a transformer. A transformer is a passive device that uses electromagnetic induction to transfer energy from one circuit to another. Transformers can be used to isolate two circuits from each other, reducing the effects of coupling capacitance. The effectiveness of a transformer can be calculated using the coupling coefficient, which is a measure of the amount of energy that is transferred between the two circuits.

In all of these solutions, the effectiveness of the solution is based on the principles of electromagnetic shielding, the distance between the shielded conductors and the electrical conductivity of the material used for shielding.

In addition to these solutions, keeping the conductors as far apart as possible and using a grounded metal shield can help to reduce coupling capacitance. The use of a metal shield can also help to reduce cross-talk and EMI.

It's also important to note that these solutions are not mutually exclusive and can be used together to provide a more effective shielding. For example, a Faraday cage combined with a twisted pair cable, will provide both electromagnetic shielding and differential signaling, which can provide a high level of shielding against coupling capacitance.

In conclusion, coupling capacitance is a common problem in electronic systems, it can cause signal interference, cross-talk and EMI. There are several solutions to this problem, such as using a Faraday cage, twisted pair cable, transformer and using grounded metal shields. The effectiveness of these solutions is based on the principles of electromagnetic shielding, distance between shielded conductors and electrical conductivity of the material used for shielding. These solutions can be used together to provide a more effective shielding. It's important to consult the datasheet of the ICs and active devices to determine the best placement and values for these components.